This hard wired type power strip is good for installation in your kitchen, cabinet and so on. It is not for normal wall outlets. There is no plug and power cord with this unit.
Features
- 3 ft (0.61m) Durable Metal Housing Power Strip
- 6 Black US Standard Outlets, Vertical Outlet Orientation
- Hard Wired without Power Cord for Mounting at Your Desired Location
- 6 Easily Punched off Knockouts on Each Side - on Top, Both Sides, the Bottom Cover and Both Ends
- Easy On/Off Back Cover (only 4 Screws)
- Wires Readily Cut for Easier Removal and Faster Installation
- Installation by professional electricians only (OR DANGER: Electric Shock)
Model #: |
EPS-H206NVW |
Description: |
24” 6 Outlet Hardwire Type Metal Power Strip
|
Power Strip Measurement: |
24" x 1.575" x 1.417” (609mm x 40mm x 36mm) * |
Outlets: |
6
|
Outlet Color: |
Black |
Outlet Orientation: |
Vertical |
Receptacle Type |
NEMA 5-15R |
Outlet Spacing |
3⅛" or 79mm (center to center) |
Knockout Cord Exit: |
6 (Top, Bottom Cover, Both Sides & Both Ends) |
Voltage Input/Output: |
110-125V 60Hz |
Current Input: |
15A |
Full Load: |
1875VA |
On/Off Switch: |
N/A |
Circuit Breaker: |
N/A |
Surge Protection: |
N/A |
Indicator: |
N/A |
Noise Filter: |
N/A |
Mounting on Back: |
N/A
|
Mounting Tabs: |
N/A |
Mounting Brackets: |
2 x 3/4 in. Spring Clips (Click Here)
|
INSTALLATION PROCEDURE:
Before installation, you will need to get a 3/4" wire clamp and 3 wire connectors from your local hardware or electric supply or home improvement store.
Minimum tool required: A fine to medium fine philips screw driver
- Turn off electricity in the house
- Decide where to place this unit
- Choose the right side for cord exit and mark on the knockout round section
- Gently punch off the knockout round section chosen with a screw driver or other tool handy
- Unscrew the cover off the back of the power strip
- Install the 3/4" wire clamp you already have
- Run the wires through the wire clamp
- Match the color of the wires and connect them properly with terminal connectors
- Tighten the wire clamp properly
- Put back the cover
- Mount the strip where you want it to be
- Turn electricity back on
WARNING:
You must be an electrician or an electric engineer to do the installation work.
Note:
* For installation purpose: The length of the power strip does not include the mounting tabs at both ends; The width does not include the size of screws; The height does not include the receptacles.
Important:
This unit is not intended for use in or around wet or potentially wet areas including, but not limited to, aquariums, saunas, showers and fountains.
We also custom manufacture for our customers.
.
|